2. When measuring the depth of the cabinet body, the table top needs to be reserved with sufficient size to facilitate the installation of the lower hanging edge strip;
3. When splicing some super-long worktops (such as L-shaped worktops), in order to ensure the flatness of the splicing worktops and the tightness of the joints, it is recommended to use strong fixing clips (A clip, F clip) to fix the quartz stone plates. In addition, when bonding the lower hanging strip, it is also necessary to use a strong fixing clip for fixing to ensure the perfect combination of the table top splicing and the gap between the table top and the lower hanging strip splicing;
4. There should be a certain distance (usually 3mm to 5mm) between the quartz stone table and the wall. After installation, the gap between the table and the wall should be evenly coated with glass glue;
5. During the installation of the table top, try to avoid cutting and opening the quartz stone in a large range on the successful site. On the one hand, it is to prevent the cutting dust from polluting the construction site, and on the other hand, it is to prevent the error caused by inaccurate cutting;
6. Due to the high hardness and high density of the quartz table, the processing technology requirements are high. Therefore, for the installation of quartz stone table, professional quartz stone installers should be contacted and professional tools should be used for installation. Do not install it blindly by yourself to avoid unnecessary trouble.